MQ-CEMS1000 Fixed Emission Source Greenhouse Gas Online Monitoring System🔍 Click to Expand
CPCB Zones
Red ZoneOrange Zone
Continuous Emission Monitoring Systems (CEMS)MQ-CEMS1000

MQ-CEMS1000 Fixed Emission Source Greenhouse Gas Online Monitoring System

by Prosoft Automation

Fixed Emission Source Greenhouse Gas Online Monitoring System heated line, pretreatment unit, condenser, flue gas analyzer, and electronic control unit. Flue gas is extracted by a sampling pump located inside the cabinet. The sample is maintained above 120°C throughout the probe and heated line. After being filtered and dedusted, the gas is directed to the condenser for moisture removal. The dried gas is then delivered to the flue gas analyzer for measurement. To ensure long-term accuracy, the system is equipped with standard gas for routine calibration. ture is measured with a thermocouple; flow velocity is determined using a differential pressure transmitter via total and static pressure; pressure is measured with a high-precision sensor; and humidity is monitored with a dedicated moisture sensor. monitoring software. 4–20 mA signals are acquired from field instruments (e.g., temperature, pressure, flow, humidity). The software, which is hosted on the industrial computer, is used to monitor and consolidate gas concentrations and system status. Reports are generated, historical data is stored, and communication with environmental agencies is supported.

Price

Get Latest Price / Request a Quote

Tailored configuration for your engineering, application, and SPCB compliance needs.

Final pricing varies by probe configuration, heated sample line lengths, and state PCB telemetry requirements.

Detection Limit

0.1 ppm

Measurement Range

0–40 ppm

Carrier Gas

None

Operating Temperature

20–50 °C

Specification Summary

Detection Limit0.1 ppm
Measurement Range0–40 ppm
Carrier GasNone
Operating Temperature20–50 °C
Response Time90100 s
Sample Extraction TypeHot-Wet

Product Description

Fixed Emission Source Greenhouse Gas Online Monitoring System heated line, pretreatment unit, condenser, flue gas analyzer, and electronic control unit. Flue gas is extracted by a sampling pump located inside the cabinet. The sample is maintained above 120°C throughout the probe and heated line. After being filtered and dedusted, the gas is directed to the condenser for moisture removal. The dried gas is then delivered to the flue gas analyzer for measurement. To ensure long-term accuracy, the system is equipped with standard gas for routine calibration. ture is measured with a thermocouple; flow velocity is determined using a differential pressure transmitter via total and static pressure; pressure is measured with a high-precision sensor; and humidity is monitored with a dedicated moisture sensor. monitoring software. 4–20 mA signals are acquired from field instruments (e.g., temperature, pressure, flow, humidity). The software, which is hosted on the industrial computer, is used to monitor and consolidate gas concentrations and system status. Reports are generated, historical data is stored, and communication with environmental agencies is supported.