SWAS Panel for HRSG Applications
Prosoft Engineering
Technical Compliance Specialist
Start reading to track sections
Primary Keyword: SWAS Panel
Secondary Keywords: SWAS Panel Maintenance, Online SWAS Panel, SWAS Panel India
Internal Link Target: /products/swas-panels
CTA: Talk to our application specialist
Introduction
A SWAS Panel for HRSG Applications is an important part of steam and water chemistry monitoring in combined cycle power plants, cogeneration facilities and industrial plants using Heat Recovery Steam Generators.
A Heat Recovery Steam Generator (HRSG) recovers heat from hot exhaust gases, typically from a gas turbine, and uses this heat to generate steam. Depending on the design, an HRSG may contain economizers, evaporators, steam drums, superheaters, reheaters and multiple pressure levels.
Because these components operate under demanding temperature and pressure conditions, maintaining appropriate water and steam chemistry is essential for protecting the HRSG and downstream steam turbine.
A properly engineered SWAS Panel (Steam and Water Analysis System) extracts representative samples from selected HRSG locations, conditions them to suitable analyzer inlet conditions and continuously monitors critical parameters such as conductivity, cation conductivity, pH, dissolved oxygen, silica and sodium.
What Is an HRSG?
An HRSG, or Heat Recovery Steam Generator, is a heat-recovery boiler used to convert waste heat into useful steam.
In a combined cycle power plant, the typical process is:
Gas Turbine → Hot Exhaust Gas → HRSG → Steam Generation → Steam Turbine → Condenser → Feedwater → HRSG
The HRSG may contain several heat-transfer sections, including:
Economizer
Evaporator
Steam drum
Superheater
Reheater
High-pressure section
Intermediate-pressure section
Low-pressure section
The actual configuration varies between plants.
Because different sections operate at different pressures and temperatures, sample points and SWAS requirements must be established from the specific HRSG design.
Why Is a SWAS Panel Important for HRSG Applications?
HRSG water-steam chemistry directly influences equipment reliability and operational performance.
Chemistry deviations can contribute to:
Corrosion
Deposits
Scaling
Heat-transfer deterioration
Tube damage
Steam contamination
Turbine deposits
Reduced equipment life
Increased maintenance
Unplanned outages
A SWAS Panel provides continuous information about selected chemistry parameters, allowing operators and chemistry personnel to identify abnormal trends more quickly.
Online measurement is particularly valuable because some contamination events can develop faster than periodic laboratory sampling can detect them.
Typical HRSG SWAS Monitoring Points
The actual sampling locations depend on HRSG design, pressure levels, cycle chemistry and the plant's monitoring philosophy.
Common locations can include:
Condensate
Condensate monitoring may help identify contamination entering the steam-water cycle.
Possible parameters include:
Conductivity
Cation conductivity
pH
Dissolved oxygen
Sodium
Feedwater
Feedwater chemistry is important for controlling corrosion and maintaining cycle chemistry.
Typical measurements may include:
pH
Conductivity
Cation conductivity
Dissolved oxygen
HP Drum Water
Where applicable, high-pressure drum-water monitoring can include:
Conductivity
pH
Silica
Phosphate where applicable
Main Steam
Steam purity is important for downstream steam-turbine protection.
Possible measurements include:
Silica
Sodium
Conductivity
Cation conductivity
Reheat Steam
Depending on the plant's chemistry-monitoring philosophy, selected reheat-steam streams may also be monitored.
Make-Up Water
Make-up water quality may be monitored using:
Conductivity
pH
Silica
Sodium
Key Parameters Measured in HRSG SWAS
ParameterTypical HRSG ApplicationpHFeedwater and condensate chemistryConductivityGeneral ionic contamination monitoringCation ConductivityDetection of ionic contaminationDissolved OxygenCorrosion-control monitoringSilicaSteam-purity and deposit-risk monitoringSodiumContamination and steam-purity monitoringPhosphateDrum-water chemistry where applicableTemperatureSample-conditioning monitoringPressureSample-system monitoringFlowSample-system performance
Not every HRSG requires all of these parameters. The final analyzer selection should be based on the HRSG chemistry program, plant design and equipment/OEM requirements.
SWAS Sample Extraction from an HRSG
The SWAS system starts at the sample extraction point.
HRSG water and steam samples can be at elevated temperature and pressure. They therefore require a carefully designed extraction and conditioning system.
A typical sample path is:
HRSG Sample Point → Isolation Valve → Pressure Reduction → Sample Cooler → Temperature Measurement → Filtration → Flow Control → Analyzer → Drain
The sample system should provide:
Representative sampling
Safe isolation
Pressure reduction
Controlled cooling
Stable flow
Appropriate sample transport
Minimal contamination
Reliable drainage
A highly accurate analyzer cannot compensate for an improperly extracted or conditioned sample.
Pressure Reduction for HRSG Samples
HRSG sample points can operate at pressures significantly higher than the acceptable inlet conditions of online analyzers.
Pressure reduction is therefore a key SWAS design function.
Possible components include:
Pressure-reducing valves
Pressure regulators
Restrictors
Needle valves
Back-pressure regulators
The pressure-control system should be selected based on:
Process pressure
Process temperature
Sample flow
Analyzer inlet requirements
Sample chemistry
Required pressure stability
Improper pressure reduction may cause flashing, unstable flow, dissolved-gas loss and unreliable measurements.
Sample Cooling in HRSG SWAS
HRSG samples may be significantly hotter than the allowable operating temperature of online analyzers.
A sample cooler is therefore commonly installed to transfer heat from the process sample to cooling water or another suitable cooling medium.
Important design considerations include:
Maximum sample temperature
Sample pressure
Sample flow
Cooling-water temperature
Cooling-water flow
Required analyzer inlet temperature
Cooler material
Fouling conditions
Heat-transfer capacity
A basic heat-transfer relationship is:
Q = m × Cp × ΔT
Actual cooler sizing should be calculated from the specific process conditions and equipment requirements.
For SWAS Panel India installations, seasonal cooling-water conditions should also be considered during engineering.
Sample Flow Control
Stable sample flow is essential for reliable online analysis.
A typical HRSG SWAS system may include:
Flowmeter
Rotameter
Flow-control valve
Needle valve
Flow switch
Low-flow alarm
The correct flow depends on the analyzer manufacturer's requirements and the complete sample-conditioning arrangement.
There is no universal SWAS flow rate that applies to every HRSG analyzer.
Insufficient flow can cause:
Slow response
Sample stagnation
Unstable measurement
Excessive transport delay
Poor cooling performance
Excessive flow can result in:
Higher sample consumption
Increased drain load
Pressure instability
Unnecessary component loading
Online SWAS Panel for HRSG Monitoring
An Online SWAS Panel continuously measures selected steam and water chemistry parameters.
Depending on the HRSG application, the panel can integrate:
pH analyzer
Conductivity analyzer
Cation conductivity analyzer
Dissolved oxygen analyzer
Silica analyzer
Sodium analyzer
Phosphate analyzer
Online analysis can provide operators with:
Real-time measurements
Chemistry trends
High/low alarms
Analyzer diagnostics
Historical data
DCS/SCADA signals
The system can therefore become an important part of the plant's overall chemistry-monitoring and control strategy.
Silica Monitoring in HRSG Applications
Silica is an important parameter in steam-cycle monitoring because it can be transported with steam under certain conditions and may contribute to deposits on turbine components.
An online silica analyzer can be installed on selected steam or water sample points.
A typical silica measurement arrangement may include:
Sample → Pressure Reduction → Cooling → Flow Control → Reagent System → Silica Analyzer → Drain
Depending on the analyzer design, the system may require:
Chemical reagents
Calibration solutions
Controlled sample flow
Temperature control
Regular maintenance
Analyzer-specific requirements should always be followed.
Sodium Monitoring in HRSG Applications
Sodium monitoring can provide useful information about certain contamination events in the steam-water cycle.
Depending on the chemistry program, sodium analyzers may be applied to:
Condensate
Feedwater
Main steam
Selected HRSG streams
Because sodium measurements can be sensitive to contamination, sample-system cleanliness is important.
Tubing, valves, fittings and other wetted components should be selected and maintained to minimize unintended contamination.
Dissolved Oxygen Monitoring
Dissolved oxygen monitoring can support corrosion-control programs in condensate and feedwater systems.
The sample system should minimize exposure to atmospheric oxygen.
Important considerations include:
Leak-free sample lines
Stable flow
Proper pressure
Appropriate temperature
Correct sensor installation
Proper calibration
Air bubbles or air ingress can produce misleading dissolved oxygen readings.
Conductivity and Cation Conductivity Monitoring
Conductivity provides an indication of ionic contamination in the water-steam cycle.
Cation conductivity can provide additional information about ionic impurities after the sample passes through an appropriate cation exchange arrangement.
These measurements may be used at selected HRSG locations such as:
Condensate
Feedwater
Steam
Other critical cycle streams
Stable temperature, flow and sensor condition are important for reliable results.
pH Monitoring in HRSG Systems
pH measurement can support control of feedwater and condensate chemistry.
Reliable pH measurement requires:
Suitable sample temperature
Stable flow
Proper sensor installation
Clean electrode
Correct calibration
Appropriate reference system
Because pH measurement can be sensitive to sample conditions, the complete sample system must be considered during SWAS design.
Phosphate Monitoring
Phosphate monitoring may be applicable where phosphate-based boiler-water treatment is used.
An online phosphate analyzer can provide continuous information about phosphate concentration in selected HRSG drum-water streams.
The system may include:
Sample conditioning
Reagent dosing
Chemical reaction
Optical measurement
Calibration
Drainage
The requirement for phosphate monitoring should be determined from the actual HRSG chemistry program rather than assuming that every HRSG uses phosphate treatment.
Dedicated vs Multiplexed HRSG SWAS
There are two common approaches to multi-point SWAS design.
Dedicated Analyzers
Each critical sample point has a dedicated analyzer.
Advantages
Continuous monitoring
Fast response
No switching delay
Reduced cross-contamination risk
Simple data interpretation
Limitations
Higher initial investment
More instruments
Larger panel
Increased maintenance requirements
Multiplexed Analysis
One analyzer can sequentially measure multiple sample streams.
Advantages
Fewer analyzers
Reduced initial cost
Compact system
Useful for selected non-critical measurements
Considerations
Valve sequencing
Sample switching time
Flushing
Cross-contamination
Transport delay
PLC programming
Analyzer stabilization time
Critical HRSG parameters should be evaluated carefully before choosing multiplexed measurement.
Sample Transport Time
The distance between the HRSG sample point and the SWAS Panel can affect measurement response.
A simplified relationship is:
Transport Time = Sample-Line Volume ÷ Sample Flow Rate
Long sample lines and low flow can significantly increase response time.
During SWAS engineering, consider:
Sample-line length
Internal tubing diameter
Flow rate
Pressure
Sample temperature
Analyzer response time
This is particularly important for alarms and contamination events where rapid detection is required.
SWAS Panel PLC and HMI
A PLC/HMI system can provide centralized monitoring and control of the HRSG SWAS.
The PLC can monitor:
Sample flow
Sample temperature
Sample pressure
Cooling-water status
Analyzer status
Valve positions
Calibration status
Alarm conditions
Communication status
The HMI can display:
Real-time analyzer readings
Trends
Alarms
Analyzer status
Sample-system status
Maintenance information
Multiplexing sequence
DCS/SCADA Integration
HRSG SWAS systems can be integrated into the plant DCS or SCADA system.
Depending on project requirements, communication can be through:
4–20 mA signals
Digital signals
Modbus RTU
Modbus TCP
Ethernet
OPC-based interfaces
Other approved communication protocols
Typical DCS signals include:
Analyzer value
High alarm
Low alarm
Analyzer fault
Sample-flow status
Sample-temperature alarm
Calibration status
Maintenance status
Communication failure
Proper signal scaling, tag mapping and alarm verification should be completed during commissioning.
SWAS Alarm Configuration for HRSG
A well-designed SWAS system should monitor both chemistry and equipment conditions.
Chemistry alarms
High conductivity
High cation conductivity
High silica
High sodium
High dissolved oxygen
High/low pH
High phosphate where applicable
Sample-system alarms
Low sample flow
High sample temperature
High sample pressure
Cooling-water failure
Filter blockage
Analyzer alarms
Sensor failure
Calibration failure
Reagent low
Analyzer fault
Communication failure
Alarm setpoints should be established according to the plant chemistry program, operating philosophy and applicable equipment requirements.
SWAS Panel Maintenance for HRSG Applications
SWAS Panel Maintenance should address the entire system, not only the online analyzers.
Daily Inspection
Check:
Sample flow
Sample pressure
Sample temperature
Leakage
Analyzer status
Alarms
Drainage
Weekly Inspection
Inspect:
Sample tubing
Valves
Flowmeters
Filters
Cooler
Electrical connections
Analyzer condition
Periodic Maintenance
Depending on the system:
Clean filters
Inspect sample lines
Clean sensors
Verify calibration
Check flow-control devices
Inspect reagent systems
Verify alarm operation
Review analyzer trends
Planned Annual Maintenance
Depending on manufacturer recommendations:
Sensor replacement
Analyzer servicing
Reagent-system servicing
Valve maintenance
Cooler inspection
Tubing replacement
PLC/HMI backup
DCS communication testing
Critical-spares review
Maintenance intervals should be based on manufacturer recommendations, operating hours and actual sample conditions.
Common HRSG SWAS Problems
1. Low Sample Flow
Possible causes:
Blocked filter
Blocked sample tubing
Valve partially closed
Pressure regulator problem
Flow-control problem
2. High Sample Temperature
Possible causes:
Insufficient cooling-water flow
Cooler fouling
High cooling-water temperature
Incorrect sample flow
Inadequate cooler capacity
3. Unstable Readings
Possible causes:
Air bubbles
Variable sample flow
Sensor fouling
Poor calibration
Sample contamination
Electrical interference
4. High Conductivity
Possible causes may include:
Cycle contamination
Condenser leakage
Chemical contamination
Sample-system contamination
5. High Silica or Sodium
Possible causes may include:
Make-up water contamination
Condenser leakage
Water-treatment problems
Steam carryover
Other cycle contamination
The actual process cause should be confirmed using supporting chemistry measurements and plant operating information.
HRSG SWAS Troubleshooting Sequence
A structured troubleshooting approach can prevent unnecessary analyzer replacement.
Use the following sequence:
Process → Sample → Conditioning → Sensor → Analyzer → Signal → DCS/SCADA
For example, if a silica analyzer shows an unexpected increase, engineers should first verify whether the process chemistry has actually changed. They should then check sample flow, pressure, temperature, sample cleanliness, analyzer condition and finally the transmitted signal.
Material of Construction
Material selection for an HRSG SWAS Panel should consider:
Sample chemistry
Temperature
Pressure
Corrosion resistance
Cleanliness
Mechanical requirements
Analyzer requirements
Potential materials include:
SS 316/316L
SS 304/304L
PTFE
PFA
PVDF
PVC
Polypropylene
Different materials may be appropriate for different components.
SWAS Panel Design Considerations for India
For SWAS Panel India projects, site-specific environmental conditions should be considered.
Important factors include:
High summer ambient temperature
Cooling-water temperature
Humidity
Dust
Electrical supply
Instrument-air availability
Cooling-water quality
Drainage
Sample-line length
Maintenance accessibility
Spare-parts availability
Indoor/outdoor installation
Area classification
The system should be engineered around actual site conditions and not simply based on a generic standard panel.
HRSG SWAS Commissioning
Before commissioning, engineers should verify the following.
Mechanical
Correct sample connections
Correct valve orientation
No leakage
Correct MOC
Proper drainage
Sample Conditioning
Correct pressure
Correct temperature
Stable flow
Adequate cooling
No flashing
No air ingress
Analyzers
Correct installation
Calibration
Configuration
Stable measurement
Alarm verification
Automation
PLC I/O
HMI
Power supply
Earthing
Communication
DCS/SCADA
Tag mapping
Signal scaling
Alarm status
Communication
Trend verification
A commissioning report should record initial readings, sample conditions and analyzer status.
How to Select a SWAS Panel for HRSG Applications
Before specifying a system, collect:
HRSG Information
HRSG manufacturer
HRSG configuration
Number of pressure levels
Sample points
Operating pressure
Operating temperature
Steam conditions
Sample Information
Sample chemistry
Sample flow
Sample-line distance
Cooling-water conditions
Drainage arrangement
Analytical Requirements
Parameters
Measuring ranges
Required accuracy
Response requirements
Analyzer technology
Automation Requirements
PLC
HMI
DCS
SCADA
Communication protocols
Alarm philosophy
Data logging
Mechanical Requirements
Panel/enclosure type
MOC
Indoor/outdoor installation
Environmental conditions
Area classification
Benefits of an Online SWAS Panel for HRSG
A properly designed Online SWAS Panel can provide:
Continuous HRSG chemistry monitoring
Early contamination detection
Improved cycle chemistry control
Better protection of HRSG components
Improved steam-purity monitoring
Turbine protection
Corrosion-risk monitoring
Scaling-risk monitoring
Faster response to abnormal conditions
Historical trend analysis
DCS/SCADA integration
Improved maintenance planning
Why Choose Prosoft Automation for HRSG SWAS Solutions?
Prosoft Automation can develop application-oriented SWAS Panel solutions for:
Combined cycle power plants
HRSG systems
Cogeneration plants
Industrial steam systems
Captive power plants
Process industries with waste-heat boilers
A typical solution can incorporate:
Sample extraction
Pressure reduction
Sample cooling
Flow control
Filtration
pH analysis
Conductivity analysis
Cation conductivity
Dissolved oxygen
Silica
Sodium
Phosphate where required
PLC/HMI
DCS/SCADA integration
Alarm monitoring
Data logging
Each system should be engineered according to actual HRSG process conditions, chemistry requirements and customer specifications.
HRSG SWAS Panel Selection Checklist
Before ordering a SWAS Panel, confirm:
HRSG configuration
Number of pressure levels
Number of sample points
Sample pressure
Sample temperature
Sample flow
Sample chemistry
Required analytical parameters
Analyzer measuring ranges
Pressure-reduction arrangement
Sample cooler requirements
Cooling-water availability
Flow-control arrangement
Filtration
Material of construction
Dedicated or multiplexed system
PLC/HMI
DCS/SCADA interface
Alarm requirements
Data logging
Calibration arrangement
Drainage
Spare parts
Maintenance access
Environmental conditions
Area classification
Frequently Asked Questions
What is a SWAS Panel used for in an HRSG?
A SWAS Panel safely extracts and conditions water and steam samples from an HRSG and continuously measures selected chemistry parameters.
Which parameters are commonly monitored?
Common parameters include pH, conductivity, cation conductivity, dissolved oxygen, silica and sodium. Phosphate may also be monitored where applicable.
Why is sample conditioning important?
HRSG samples can be at high temperature and pressure. Pressure reduction, cooling and flow control are necessary to deliver a suitable sample to the analyzer.
Is an Online SWAS Panel necessary for every HRSG?
The exact requirement depends on the plant's chemistry program, HRSG design, monitoring philosophy and project specifications.
Why is silica monitored in HRSG systems?
Silica monitoring can support steam-purity control because silica can be transported with steam under certain conditions and may contribute to deposits on turbine components.
Why is sodium monitored?
Sodium can be a useful indicator of certain contamination events and may be monitored in selected condensate, feedwater or steam streams.
Can one analyzer monitor several HRSG sample points?
Yes. Multiplexed SWAS systems can sequentially connect an analyzer to multiple sample streams. However, switching time, flushing, cross-contamination and response time must be considered.
How often should SWAS Panel Maintenance be performed?
Maintenance frequency depends on analyzer technology, sample quality, operating conditions and manufacturer recommendations. Regular inspections should be combined with planned preventive maintenance.
Can an HRSG SWAS Panel be connected to DCS?
Yes. A SWAS system can be designed to communicate with the plant DCS or SCADA through suitable analog, digital or communication interfaces.
Can Prosoft Automation supply HRSG SWAS systems in India?
Yes. Prosoft Automation can provide application-oriented SWAS Panel India solutions for HRSG and combined cycle applications based on actual process and analytical requirements.
Conclusion
A SWAS Panel for HRSG Applications provides continuous monitoring of critical steam and water chemistry parameters and supports reliable operation of HRSGs and downstream steam-cycle equipment.
The effectiveness of the system depends on proper sample extraction, pressure reduction, cooling, flow control, filtration, analyzer selection, calibration and automation. Sample-system design is just as important as analyzer accuracy.
Regular SWAS Panel Maintenance should cover the complete sample-conditioning system as well as the analytical instruments.
A correctly engineered Online SWAS Panel can help plant operators identify contamination, chemistry deviations and abnormal operating conditions at an early stage, supporting improved reliability and equipment protection.
Need Help Selecting an HRSG SWAS Panel?
Every HRSG has different sample conditions, pressure levels, temperature ranges and chemistry-monitoring requirements.
Talk to our application specialist to discuss your HRSG sample points, required parameters and SWAS configuration.