Introduction

Accurate steam and water chemistry monitoring is essential for protecting boilers, HRSGs, turbines, condensers and other components of a power-generation water-steam cycle. Among the most important measurements used in high-purity cycle chemistry is cation conductivity.

However, dissolved gases—particularly carbon dioxide—can influence conductivity measurements. In applications where a more specific assessment of ionic contamination is required, degassed cation conductivity can provide additional information.

A properly designed SWAS Panel can incorporate degassed cation conductivity along with specific conductivity, cation conductivity, pH, dissolved oxygen, silica and sodium measurements.

This article explains what degassed cation conductivity means, how it differs from conventional cation conductivity, why degassing is used, how the measurement system works, and what should be considered when designing and maintaining an Online SWAS Panel.


What Is Degassed Cation Conductivity?

Degassed cation conductivity is a conductivity measurement performed after:

  1. The sample passes through a cation-exchange system.

  2. Dissolved gases—particularly carbon dioxide—are removed or reduced.

  3. The conductivity of the treated sample is measured.

The simplified measurement sequence is:

Process Sample

↓

Pressure Reduction

↓

Cooling

↓

Cation Exchange

↓

Degassing

↓

Conductivity Measurement

The exact arrangement can vary depending on the analyzer manufacturer and SWAS design.

The objective is to reduce the influence of dissolved carbon dioxide on the conductivity measurement so that the remaining conductivity provides a better indication of ionic contamination.


Why Is Degassing Necessary?

Carbon dioxide can dissolve in water and form carbonic-acid-related species.

The simplified reaction is:

CO₂ + H₂O ⇌ H₂CO₃

Carbonic acid can dissociate to produce hydrogen and bicarbonate/carbonate species.

These ionic species contribute to conductivity.

Consequently, a cation conductivity measurement can include a contribution associated with dissolved carbon dioxide.

If the objective is to distinguish potentially significant strong-acid contamination from the conductivity contribution associated with carbon dioxide, degassing can provide additional diagnostic information.


Cation Conductivity vs Degassed Cation Conductivity

The fundamental difference is the additional degassing step.

ParameterCation ConductivityDegassed Cation ConductivityDirect conductivity measurementNoNoCation exchangeYesYesDegassingNoYesCO₂ influenceCan contributeReduced after effective degassingMain purposeDetect ionic contamination after cation exchangeFurther evaluate contamination with reduced CO₂ contributionSystem complexityModerateHigherMaintenance requirementSensor + cation exchangerSensor + cation exchanger + degassing systemTypical applicationCycle chemistryDiagnostic/high-purity cycle chemistry

The two measurements should therefore be considered complementary.


Understanding the Measurement Principle

Consider a water sample containing sodium chloride.

Initially:

NaCl → Na⁺ + Cl⁻

When the sample passes through the cation exchanger, sodium is exchanged for hydrogen:

Na⁺ → H⁺

The chloride remains in solution.

The resulting hydrogen/chloride ionic contribution produces increased conductivity.

Now consider dissolved carbon dioxide.

Carbon dioxide can contribute to conductivity through the formation of carbonic-acid-related species.

If the sample is subsequently degassed, a significant portion of dissolved CO₂ can be removed.

The resulting conductivity can therefore be lower than the non-degassed cation conductivity when CO₂ is contributing significantly.

The difference between the two measurements can provide useful diagnostic information.


What Does Degassed Cation Conductivity Tell You?

Degassed cation conductivity can help distinguish between different contributors to cation conductivity.

For example:

High Cation Conductivity + Lower Degassed Cation Conductivity

This can indicate that dissolved CO₂ is making a meaningful contribution.

High Cation Conductivity + High Degassed Cation Conductivity

This may suggest that ionic contamination remains significant even after degassing.

Potential sources can include:

  • Chloride

  • Sulphate

  • Other strong-acid anions

  • Cooling-water contamination

  • Condenser leakage

  • Makeup-water contamination

  • Process contamination

The actual diagnosis must always consider other plant chemistry measurements and operating conditions.


Where Is Degassed Cation Conductivity Used?

Degassed cation conductivity is particularly useful in applications where very low levels of contamination need to be monitored.

Typical applications can include:

  • Thermal power plants

  • Combined-cycle power plants

  • HRSG systems

  • High-pressure boiler systems

  • Steam turbine cycles

  • Condensate systems

  • Feedwater systems

  • High-purity water systems

It can be especially useful when operators need to investigate whether an increase in cation conductivity is associated primarily with dissolved carbon dioxide or with other ionic contaminants.


Degassed Cation Conductivity in a SWAS Panel

A properly engineered SWAS Panel integrates the degassed conductivity system into the overall sample-conditioning architecture.

A typical arrangement may include:

Process Sample

→ Sample Isolation

→ Pressure Reduction

→ Sample Cooler

→ Temperature Measurement

→ Flow Control

→ Cation Exchanger

→ Degassing System

→ Conductivity Cell

→ Drain

The actual sequence may differ according to the selected analyzer and application.

The sample-conditioning system must be designed as a complete system rather than simply connecting a conductivity sensor to the process sample.


Sample Extraction Is Critical

The quality of the measurement begins at the sample point.

The sample should be:

  • Representative of the process stream

  • Extracted safely

  • Transported with minimal delay

  • Compatible with the sample-line material

  • Properly pressure-reduced

  • Properly cooled

  • Delivered at the required flow

A poor sample point can produce misleading results regardless of how sophisticated the conductivity analyzer is.


Pressure Reduction

Power-plant samples can originate from high-pressure and high-temperature locations.

The sample must therefore be brought into an appropriate operating range before entering the analyzer.

Pressure-reduction equipment can include:

  • Pressure-reducing valves

  • Needle valves

  • Regulators

  • Back-pressure control

  • Multi-stage pressure reduction where required

The selected arrangement should account for:

  • Upstream pressure

  • Downstream pressure

  • Sample temperature

  • Required flow

  • Flashing risk

  • Valve material

  • Pressure rating

There is no universal SWAS pressure setting. The design must be based on actual process conditions and analyzer requirements.


Sample Cooling

Sample cooling is normally required before conductivity measurement when the source sample is too hot for the analyzer.

A sample cooler may use plant cooling water to reduce the sample temperature.

Important design factors include:

  • Sample inlet temperature

  • Required outlet temperature

  • Sample flow

  • Cooling-water temperature

  • Cooling-water flow

  • Heat-transfer duty

  • Cooler material

  • Pressure rating

The basic heat-transfer relationship can be expressed as:

Q = m × Cp × ΔT

where:

  • Q = heat-transfer duty

  • m = mass flow

  • Cp = specific heat

  • ΔT = temperature change

Actual cooler sizing should be based on engineering calculations and the manufacturer's requirements.


Cation Exchange System

The cation exchanger is central to the measurement.

Its purpose is to exchange dissolved cations for hydrogen ions before conductivity measurement.

Important design considerations include:

  • Resin type

  • Resin capacity

  • Column volume

  • Sample flow

  • Pressure drop

  • Temperature

  • Resin condition

  • Column accessibility

  • Replacement procedure

The cation exchanger should be installed in a way that allows inspection and maintenance without unnecessarily disturbing the rest of the SWAS system.


Degassing System

The degassing stage removes dissolved gases from the sample before the final conductivity measurement.

Different analyzer manufacturers may use different approaches.

The system may involve:

  • Gas-permeable membrane technology

  • Vacuum-assisted degassing

  • Gas stripping

  • Controlled sample exposure

  • Other proprietary arrangements

The exact technology should be selected according to the analyzer manufacturer's design.

The important engineering objective is to achieve repeatable removal of dissolved gases without introducing contamination into the sample.


Why Carbon Dioxide Matters

CO₂ is particularly important because it can enter the water-steam cycle from several sources.

Possible sources include:

  • Air ingress

  • Condenser vacuum-system leakage

  • Makeup-water chemistry

  • Atmospheric exposure

  • Decomposition of carbonate/bicarbonate species

  • Other process-related sources

CO₂-related conductivity can therefore complicate the interpretation of conventional cation conductivity.

Degassed cation conductivity helps provide another diagnostic perspective.


Comparing Three Conductivity Measurements

It is useful to understand the relationship between:

Specific Conductivity

Measured directly on the sample.

It provides an overall indication of ionic conductivity.

Cation Conductivity

Measured after cation exchange.

It increases sensitivity to certain anionic contaminants.

Degassed Cation Conductivity

Measured after cation exchange and subsequent degassing.

It reduces the contribution associated with dissolved CO₂ and can therefore provide additional diagnostic information.

These measurements should not be interpreted independently.


Using Conductivity Measurements Together

A modern Online SWAS Panel can trend multiple conductivity measurements together.

For example:

Specific Conductivity

Cation Conductivity

Degassed Cation Conductivity

pH

Dissolved Oxygen

Silica

Sodium

This combination can provide much better diagnostic information than any single measurement.

Operators can examine trends rather than relying only on instantaneous readings.


Example of Diagnostic Interpretation

Consider a situation where cation conductivity increases unexpectedly.

Step 1 — Check Specific Conductivity

If specific conductivity also increases, an actual increase in ionic contamination may be occurring.

Step 2 — Check Cation Conductivity

If cation conductivity increases significantly, investigate possible anionic contamination.

Step 3 — Check Degassed Cation Conductivity

If degassed cation conductivity remains relatively low compared with cation conductivity, CO₂ may be contributing to the difference.

Step 4 — Check Other Parameters

Review:

  • pH

  • Sodium

  • Silica

  • Chloride, if available

  • Sulphate, if available

  • Dissolved oxygen

  • Condenser operating condition

  • Makeup-water quality

Step 5 — Check the SWAS System

Before concluding that the process chemistry has changed, verify:

  • Sample flow

  • Temperature

  • Pressure

  • Cation resin

  • Conductivity sensor

  • Sample tubing

  • Drainage

  • Electrical connections

This process helps distinguish a real chemistry event from a sample-system or analyzer problem.


Degassed Cation Conductivity and Condenser Leakage

Condenser leakage is a major concern in many power plants.

Cooling water can contain dissolved salts and other ionic contaminants.

If cooling water enters the condensate, conductivity may increase.

Cation conductivity can be particularly useful for detecting contamination associated with strong-acid anions.

Degassed cation conductivity provides additional information by reducing the influence of dissolved CO₂.

However, no single conductivity measurement should be used as the sole proof of condenser leakage. Plant chemistry trends and other process information should also be evaluated.


Degassed Cation Conductivity in HRSG Systems

Combined-cycle power plants use Heat Recovery Steam Generators to recover energy from gas-turbine exhaust.

The water-steam cycle typically includes:

  • Condenser

  • Condensate system

  • Feedwater

  • Economizer

  • Evaporator

  • Steam drum

  • Superheater

  • Reheater

Because modern HRSG systems can operate with high-purity chemistry requirements, continuous monitoring can be important.

A SWAS Panel India solution for an HRSG application may integrate:

  • Specific conductivity

  • Cation conductivity

  • Degassed cation conductivity

  • pH

  • Dissolved oxygen

  • Silica

  • Sodium

  • Other required parameters

The exact parameter list should be established from the plant chemistry program and equipment requirements.


Temperature Control for Degassed Cation Conductivity

Temperature stability is important because conductivity is temperature-dependent.

The system should therefore provide appropriate:

  • Sample cooling

  • Temperature measurement

  • Temperature compensation

  • Flow control

The analyzer's specified operating range should always be followed.

Unstable sample temperature can appear as an unstable chemistry reading even when the process itself is stable.


Sample Flow Requirements

Stable flow is important for the complete measurement chain.

Flow affects:

  • Sample transport time

  • Cooling performance

  • Cation-exchange performance

  • Degassing performance

  • Conductivity-cell response

  • Measurement stability

There is no universal SWAS sample flow rate.

The required flow should be determined from:

  • Analyzer manufacturer's specification

  • Cation-column requirements

  • Degassing system requirements

  • Cooler design

  • Tubing dimensions

  • Sample pressure

  • Process conditions


Sample-Line Material Selection

Sample-line materials should be selected to minimize contamination and maintain sample integrity.

Common materials can include:

  • Stainless steel

  • PTFE

  • PFA

  • Other application-compatible polymers

The final material should be selected according to:

  • Water chemistry

  • Temperature

  • Pressure

  • Required cleanliness

  • Sample conductivity

  • Analyzer requirements

For very-low-conductivity applications, contamination from inappropriate materials or fittings can become significant.


SWAS Panel Maintenance for Degassed Cation Conductivity

An effective SWAS Panel Maintenance program should cover the entire measurement chain.

Cation Exchanger

Check:

  • Resin condition

  • Resin capacity

  • Column condition

  • Flow

  • Leakage

  • Replacement requirement

Degassing System

Check:

  • Degassing performance

  • Membrane/system condition where applicable

  • Vacuum or gas system where applicable

  • Connections

  • Leakage

  • Flow

Conductivity Cell

Check:

  • Cell condition

  • Cleanliness

  • Cable

  • Connector

  • Calibration/verification

Sample System

Check:

  • Pressure

  • Temperature

  • Flow

  • Cooler

  • Filters

  • Tubing

  • Valves

  • Drain


Common Problems and Troubleshooting

Problem 1: Cation Conductivity High, Degassed Value Normal

Possible causes include:

  • Increased dissolved CO₂

  • Air ingress

  • Condenser-related conditions

  • Makeup-water changes

Verify the process chemistry and sample system before drawing a conclusion.


Problem 2: Both Cation and Degassed Cation Conductivity High

Possible causes include:

  • Ionic contamination

  • Chloride/sulphate contamination

  • Condenser leakage

  • Makeup-water contamination

  • Chemical contamination

Review other chemistry parameters and plant operating conditions.


Problem 3: Degassed Conductivity Unstable

Check:

  • Sample flow

  • Degassing system

  • Temperature

  • Pressure

  • Cation resin

  • Conductivity sensor

  • Electrical connections


Problem 4: Conductivity Suddenly Drops

Possible causes include:

  • Change in process chemistry

  • Flow interruption

  • Cation-resin condition

  • Degassing-system change

  • Sensor problem

  • Sample-line problem


Calibration and Verification

Conductivity systems should be calibrated or verified according to the manufacturer's procedure.

Before performing calibration:

  1. Check sample flow.

  2. Check temperature.

  3. Inspect the conductivity cell.

  4. Verify the cation exchanger.

  5. Check the degassing system.

  6. Confirm the correct calibration standard.

  7. Perform calibration according to the instrument manual.

  8. Verify the result.

  9. Record the activity.

For low-conductivity measurements, the cleanliness of calibration equipment and standards is particularly important.


DCS and SCADA Integration

A modern Online SWAS Panel can transmit degassed cation conductivity to the plant automation system.

Typical signals may include:

  • Conductivity value

  • Cation conductivity

  • Degassed cation conductivity

  • Temperature

  • Flow

  • Analyzer status

  • Alarm status

  • Calibration status

  • Maintenance status

Communication can use:

  • 4–20 mA

  • Modbus RTU

  • Modbus TCP

  • Ethernet

  • Other plant-approved protocols

Historical trending can help operators identify gradual changes before they become major chemistry events.


Alarm Management

Potential alarms include:

  • High cation conductivity

  • High degassed cation conductivity

  • High specific conductivity

  • Low sample flow

  • High sample temperature

  • Analyzer fault

  • Sensor fault

  • Cation resin service

  • Degassing system fault

  • Communication failure

Alarm limits should be determined by the plant chemistry program and applicable equipment/OEM requirements. Generic values should not automatically be applied to every plant.


Maintenance Records

Good documentation is an important part of SWAS Panel Maintenance.

Records can include:

  • Conductivity calibration

  • Cation-resin replacement

  • Degassing-system maintenance

  • Sensor replacement

  • Sample cooler maintenance

  • Flow checks

  • Temperature checks

  • Alarm testing

  • Analyzer fault history

  • DCS/SCADA verification

Historical records make it easier to identify gradual degradation and recurring problems.


Selection Checklist for Degassed Cation Conductivity

When specifying a system, consider:

Process Data

  • Sample source

  • Pressure

  • Temperature

  • Flow

  • Sample chemistry

Measurement Requirements

  • Specific conductivity

  • Cation conductivity

  • Degassed cation conductivity

  • Required accuracy

  • Measurement range

Sample Conditioning

  • Pressure reduction

  • Cooling

  • Flow control

  • Filtration

  • Cation exchange

  • Degassing

Mechanical Design

  • Tubing material

  • Valve material

  • Panel construction

  • Drainage

  • Accessibility

Automation

  • PLC/HMI

  • DCS/SCADA

  • Communication protocol

  • Alarm requirements

  • Data logging

Maintenance

  • Resin replacement

  • Sensor maintenance

  • Degassing-system maintenance

  • Calibration

  • Spare parts


Dedicated vs Multiplexed Measurement

For plants with several sample points, degassed cation conductivity can be configured using dedicated or multiplexed arrangements.

Dedicated System

Each sample has a dedicated measurement channel.

Advantages:

  • Continuous monitoring

  • Faster response

  • No switching delay

  • Lower cross-contamination risk

Multiplexed System

One analyzer sequentially monitors several samples.

Advantages:

  • Lower analyzer count

  • Lower initial investment

  • Compact system

However, multiplexed systems require careful engineering of:

  • Switching valves

  • Flushing

  • Sample transport time

  • Cross-contamination

  • Measurement sequence

  • Response time

Critical applications may favor dedicated measurement.


Best Practices

For reliable degassed cation conductivity monitoring:

  1. Select a representative sample point.

  2. Engineer pressure reduction correctly.

  3. Provide suitable sample cooling.

  4. Maintain stable flow.

  5. Use appropriate sample-line materials.

  6. Maintain the cation exchanger properly.

  7. Maintain the degassing system.

  8. Keep the conductivity cell clean.

  9. Prevent air ingress.

  10. Verify temperature measurement.

  11. Follow analyzer calibration procedures.

  12. Trend specific, cation and degassed cation conductivity together where appropriate.

  13. Integrate alarms into the DCS/SCADA system.

  14. Investigate sample-system problems before replacing an analyzer.

  15. Maintain adequate critical spares.


How Prosoft Automation Can Help

Prosoft Automation can support customers in designing application-specific SWAS Panel systems for steam and water chemistry monitoring.

Depending on the application, a system can integrate:

  • Specific conductivity

  • Cation conductivity

  • Degassed cation conductivity

  • pH

  • Dissolved oxygen

  • Silica

  • Sodium

  • Phosphate

  • Sample coolers

  • Pressure-reduction systems

  • Flow-control systems

  • Cation-exchange systems

  • PLC/HMI

  • DCS/SCADA integration

  • Alarm and data-logging functions

The final configuration can be engineered around the customer's sample points, process conditions, required parameters and plant automation philosophy.

Get a free site-application consultation to discuss your SWAS requirements, sample conditions and required online chemistry measurements.


Benefits of Degassed Cation Conductivity Monitoring

A properly designed system can help plants:

  • Improve cycle-chemistry diagnostics

  • Reduce the influence of dissolved CO₂

  • Investigate conductivity excursions

  • Identify potential contamination

  • Support condenser-leakage investigations

  • Improve steam-water chemistry monitoring

  • Protect boilers and turbines

  • Improve trend analysis

  • Support preventive maintenance

  • Provide additional information for plant operators


Frequently Asked Questions

What is degassed cation conductivity?

It is conductivity measured after the sample has undergone cation exchange and subsequent degassing to reduce the contribution from dissolved gases, particularly CO₂.

What is the difference between cation conductivity and degassed cation conductivity?

Cation conductivity is measured after cation exchange. Degassed cation conductivity adds a degassing step before the final conductivity measurement.

Why is CO₂ important?

Dissolved CO₂ can form carbonic-acid-related ionic species that contribute to conductivity. Removing dissolved CO₂ can therefore provide additional diagnostic information.

Is degassed cation conductivity better than cation conductivity?

Not necessarily. They serve complementary purposes. Degassed cation conductivity provides additional information that can help interpret the cation conductivity result.

Is degassed cation conductivity required in every SWAS Panel?

No. Its requirement depends on the plant chemistry program, process conditions and monitoring objectives.

Where is degassed cation conductivity commonly used?

It is particularly relevant to high-purity steam-water cycle applications such as thermal power plants, combined-cycle plants and HRSG systems.

Does degassed cation conductivity require a cation exchanger?

Yes. Cation exchange is normally performed before the degassing and conductivity measurement stages.

Can degassed cation conductivity be connected to a DCS?

Yes. Depending on the analyzer and plant architecture, the measurement can be integrated through analog and/or digital communication.

How often should the cation resin be replaced?

There is no universal replacement interval. Resin life depends on sample chemistry, loading, flow and system design. Follow the manufacturer's recommendations and monitor performance.

What should I check if the measurement is unstable?

Start with the complete sample path:

Process → Sample Point → Pressure → Cooling → Flow → Cation Exchanger → Degassing → Sensor → Analyzer → Signal → DCS/SCADA

This approach helps separate actual process chemistry changes from sample-system or instrument problems.


Conclusion

Degassed cation conductivity is an advanced and useful measurement for steam-water cycle chemistry applications where operators need additional information beyond conventional conductivity and cation conductivity.

The key distinction is simple:

Specific Conductivity: Direct conductivity measurement.

Cation Conductivity: Conductivity after cation exchange.

Degassed Cation Conductivity: Conductivity after cation exchange and removal/reduction of dissolved gases such as CO₂.

When properly integrated into an Online SWAS Panel, these measurements can provide valuable information for detecting and investigating contamination, condenser-related problems and changes in high-purity cycle chemistry.

Reliable performance depends not only on the conductivity analyzer but also on representative sampling, pressure reduction, cooling, flow control, cation exchange, degassing, sensor condition, calibration and proper SWAS Panel Maintenance.

For thermal power plants, combined-cycle plants, HRSG systems and other industrial applications, Prosoft Automation can help develop a SWAS solution based on actual process conditions and monitoring requirements.